Technical Specification
Material : Brass (IS-319) Standard (Al. / S.S. / M.S. also available)
Plating : Nickle Plated Standard (Chrome also available)
Entry Threads : Metric Threads with 1.5 pitch as per IS 4218 standard
Sealing Rubber Ring : Synthetic  / Natural
Gland Standard : IS 12943:1990
Ingress Protection : IP 60 as per IS 12063


Single Compression Glands are weather proof and dust proof (IP-60) which can be used in normal climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere. 

These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores.

Single Compression Glands are designated as below : 

SCGn, where

SC Single Compression
G Gland
n(n=1, 2,....20) Gland Size For eg.(SCG1, SCG2,...... SCG20)

PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately.

  • (a) Pass the Compression Nut (Part-5),one Metal Washer (Part-3) & Outer Seal Ring (Part-4) /in succession order over the outer sheath of the cable before commencing to strip the cable
  • (b) Remove the outer sheath to the  desired length depending on the length of the beds required.
  • (c) Pass the 2nd Metal Washer (Part-3) over the exposed armour and then splay out the armour wire one by one.Now cut the armour wire according to the size of the metal washer and bend the same.pass the 3rd Metal Washer (Part-3) over the inner sheath and place it over the bended armour ,so that the armour wires are now secure between the two Metal Washer.
  • (d) Push the assembly through the Gland Body (Part-2)and tighten the Compression Nut(Part-5).While doing so the outer seal ring will expand in radial direction and will grip the cable.This will ensure dust proof entry of the cable.
  • (e) Finally apply the fitted gland assembly to the extreme with the entry thread provided,if the enclosure does not have threaded entry than tight the gland assembly with the Check Nut (Part-1).


SC Heavy Duty

1. Check Nut 2. Glad Body 3. Metal Washer 4.Metal Washer 5. Outer Sealing Ring
1. Check Nut 2. Glad Body 3. Metal Washer 4.Metal Washer 5. Outer Sealing Ring
6.Metal Washer 7. Compression Nut
6.Metal Washer 7. Compression Nut


Suitable Cable Overall Dia Size Code D1 Nipple Entry  Thread in Metrics D2 Dia. D3 Dia. D4(A/F) D5 (A/C) L1 Length
From To SCG mm Ø mm
Ø mm mm mm mm
9.0 12.0 SCG 1 16 x 1.5 12.0 16.0 22.0 25.5 9.0
12.0 15.0 SCG 2 16 x 1.5 12.0 18.5 25.0 29.0 9.0
12.0 15.0 SCG 3 20 x 1.5 15.0 18.5 25.0 29.0 9.0
15.0 18.0 SCG 4 20 x 1.5 15.0 24.0 30.0 34.5 9.5
16.0 20.0 SCG 5 25 x 1.5 20.5 24.0 31.5 36.0 9.0
20.0 24.0 SCG 6 25 x 1.5 20.5 28.5 35.0 40.0 10.0
24.0 28.0 SCG 7 32 x 1.5 27.0 33.0 40.0 46.0 12.0
28.0 32.0 SCG 8 40 x 1.5 34.0 37.0 46.0 53.0 12.0
33.0 37.0 SCG 9 40 x 1.5 34.0 41.0 50.0 57.5 12.0
37.0 42.0 SCG 10 50 x 1.5 44.0 47.0 58.0 67.0 13.0
43.0 48.0 SCG 11 50 x 1.5 44.0 52.0 65.0 75.0 13.0
49.0 54.0 SCG 12 63 x 1.5 55.0 61.5 73.0 84.0 14.0
55.0 60.0 SCG 13 63 x 1.5 55.0 65.0 77.0 89.0 14.0
61.0 66.0 SCG 14 75 x 1.5 68.0 71.0 85.0 98.0 15.0
67.0  72.0 SCG 15 75 x 1.5 67.0 76.0 90.0 104.0 15.0
73.0 78.0  SCG 16 82 x 1.5 73.0 82.0 97.0 112.0 17.0
79.0 84.0 SCG 17 90 x 1.5 81.0 91.0 108.0 124.0 19.0
84.5 92.0 SCG 18 100 x 1.5 91.0 98.0 117.0 135.0 20.0
93.0 100.0 SCG 19 110 x 1.5 100.0 107.0 127.0 146.0 25.0
101.0  115.0 SCG 20 125 x 1.5 113.0 118.0 142.0 164.0 25.0